Seminare
Seminare

Certified Network Cabling Design Professional - CNCDP® (exam included) - Course Language: English

Webinar - PROKODA GmbH

Certified Network Cabling Design Professional - CNCDP® (exam included) - Course Language: English
Termin Ort Preis*
10.03.2025- 11.03.2025 online 1.963,50 €
*Alle Preise verstehen sich inkl. MwSt.

Detaillierte Informationen zum Seminar

Inhalte:

Agenda

Introduction to Structured Cabling System (SCS) 

  • Brief history of SCS
  • Basic copper and fibre transmission
  • Copper and fibre cabling
  • Single and multimode fibre
  • Step/graded index multimode fibre
  • Difference between Commercial Wiring and data centre cabling
  • Development of standards
  • Role of standards
  • ANSI/TIA 568 standard
  • Common standards
  • The new usage of cabling to support Smart building

Horizontal and Administration - Commercial Building

  • Standard diagram recap: ANSI/TIA-568
  • Functional elements and example
  • Scenario A: Determine the number of work areas
  • Scenario B: Determine the number of user locations
  • Zone wiring
  • Administration: Interconnect and cross-connect
  • Angled and flat panels
  • Creating a cabling schematic design
  • Convert schematic into physical layout
  • Calculating the material list

Horizontal and Administration - Data Centre

  • Standard diagram recap: TIA-942
  • Basic/Reduced/Typical data centre setup
  • Traditional 3 layers network design/ Spine and Leaf network design
  • Select termination hardware
  • Administration design
  • ToR/EoR/Spine & Leaf cabling design
  • Network and cabling resiliency
  • Create cabling schematic design for ToR/EoR
  • Convert into patch panel/rack layout
  • Calculate the material list for ToR/EoR

Building Backbone - Commercial Building 

  • Backbone diagram
  • Calculate the copper backbone requirements per Telecom Room (TR)
  • Calculate the fibre backbone requirements per Telecom Room
  • Summarize the building backbone requirements
  • Recognised cables
  • Backbone Patch panels
  • The maximum backbone distances
  • Create cabling schematic design
  • Converting the schematic design into patch panel/ rack layout

Building Backbone - Data Centre

  • TIA-942 based backbone topology
  • TIA-942 backbone requirements
  • Recognised backbone cable
  • ToR/EoR/Spine and Leaf
  • Backbone distance estimation
  • Resiliency of backbone cable routes
  • Creating cabling schematic design
  • Converting the schematic design into patch panel/ rack layout
  • Field and Fusion Termination for fibre connectors
  • Pre-terminated fibre trunk and copper cables 

Architectural Considerations

  • ANSI/TIA569-D Cable pathway and spaces
  • Common requirements for the rooms
  • Definition of the rooms
  • Entrance Room/Demarcation
  • Ceiling and floor pathways types
  • Cable trays/basket/ladder/conduit
  • Inner duct/sleeve/slot
  • Calculating of pathway size
  • Cable run best practices
  • Cable management/AIM
  • Grounding and bonding
  • Separation distance requirements for copper cabling to power cabling
  • Fire stopping
  • Fire rated barrier
  • Fire rated jacket cable

Campus / Outdoor Backbone

  • Common campus cable installation and cable types : Aerial cable / Direct-buried / Underground in-conduit
  • Outdoor cable installation planning
  • Lightning / surge protection
  • Approved ground for surge protector
  • Creating a schematic diagram
  • Converting a schematic into a physical layout

Site Inspection and Testing

  • Visual site inspection notes
  • Installation common issues
  • Copper testing standard
  • Permanent link / Channel / Patch cord / MPTL testing configuration
  • Fibre connectors
  • Fibre testing standard
  • Tier 1 & 2 certification
  • Fibre link definition
  • Fibre testing steps
  • Fibre inspection and cleaning
  • Calibrating the test sets - 3 methods
  • Setting up mandrel for testing
  • Fibre loss budget calculation
  • G.657 Bend insensitive fibre
  • Optical Time-Domain Reflectometer (OTDR)

Prüfung

Certified Network Cabling Design Professional (CNCDP®)

The exam is a 60-minute closed book exam, with 40 multiple-choice questions. The candidate requires a minimum of 27 correct answers to pass the exam.

Teilnahmevoraussetzungen:

There is no specific prerequisite for the CNCDP® course. However, participants who already have at least one or two years’ experience in a IT, data centre or facilities environment may be best suited. Those with no experience just yet are most welcome to participate.

Zielgruppe:

The primary audience for this course is any IT, facilities or data centre professional, consultant and/or those who work in network cabling system design, implementation and operation. 

After completion of the course the participant will be able to:

  • Understand the various standards for network cabling systems, the models and how to apply these to the network design.
  • Design the user cabling and patching system for commercial buildings.
  • Design the network cabling and patching system for data centres.
  • Design the backbones for both indoor and outdoor cabling.
  • Select the proper cabling containment/ pathways for network installations.
  • Apply the correct installation practices and avoid common mistakes.
  • Define the right testing criteria and methods for copper and fiber systems
Nach unten
Nach oben
Wir setzen Analyse-Cookies ein, um Ihre Zufriedenheit bei der Nutzung unserer Webseite zu verbessern. Diese Cookies werden nicht automatisiert gesetzt. Wenn Sie mit dem Einsatz dieser Cookies einverstanden sind, klicken Sie bitte auf Akzeptieren. Weitere Informationen finden Sie hier.
Akzeptieren Nicht akzeptieren









Um Spam abzuwehren, geben Sie bitte die Buchstaben auf dem Bild in das Textfeld ein:

captcha



Bei der Verarbeitung Ihrer personenbezogenen Daten im Zusammenhang mit der Kontaktfunktion beachten wir die gesetzlichen Bestimmungen. Unsere ausführlichen Datenschutzinformationen finden Sie hier. Bei der Kontakt-Funktion erhobene Daten werden nur an den jeweiligen Anbieter weitergeleitet und sind nötig, damit der Anbieter auf Ihr Anliegen reagieren kann.







Um Spam abzuwehren, geben Sie bitte die Buchstaben auf dem Bild in das Textfeld ein:

captcha